Virtual Provisioning in Vmax

By | September 30, 2011

Virtual Provisioning in Vmax

Below are the steps involved to setup Virtual Provisioning. Here I am assuming that there is an existing storage group called MyStorageGroup and we need to allocate the new thin device to that SG.

1. Create a Thin Pool

create pool ThinPool1 type =thin;

2. Create DATA Devices

Create 4 x 2GB Raid-5 , DATA Devices

create dev count=4, config=RAID-5, data_member_count=3, attribute=datadev, emulation=FBA, size=2GB, disk_group=1;

3. Add DATA Devices to Thin Pool

0A00:0A03 are DATA devices created in the previous step

add dev 0A00:0A03 to pool ThinPool1 type=thin member_state =ENABLE;

4. Create Thin Devices

Create 2 thin devices of size 4GB each

create dev count=2, config=TDEV, emulation=FBA, size=4GB;

5. Bind Thin Devices to Thin Pool

0A04:0A05 are thin devices created in the previous step

bind tdev 0A04:0A05 to pool ThinPool1;

6. Add Thin Devices to Storage Group

Here we are adding the thin devices 0A04:0A05, to the Storage Group MyStorageGroup

symaccess -sid 1234 -name MyStorageGroup -type storage add devs 0A04:0A05;